Test Stations

All Test Stations
FCTS-165
165W · EIS capable
FCTS-400
400W · Short stack capable

Need a custom test configuration?

Custom Request →
Engineers working on Hydrogenergy Test Station
Test Stations · FCTS-400

FCTS-400 Fuel Cell Test Station

400W testing for short stacks and large active area cells.

The FCTS-400 is a high-power PEM fuel cell test station for cells up to 70 cm² and short stacks. With an 80A / 400W electronic load, SS316 humidifiers with 800W heaters, larger mass flow controllers and a 150V voltage range, the FCTS-400 handles more demanding characterization protocols that the FCTS-165 cannot. Ships from India with on-site commissioning.

Request a Quote →
FCTS-400

Specifications

Max. Load Current80 A
Max. Load Power400 W
Voltage Range0.25 – 150 V
Min. Load Resistance0.0125 Ω
Current Resolution2 mA (H Range), 0.02 A (L Range)
Current Accuracy±0.2% of set + 0.1% of f.s
Voltage Accuracy±0.1% of set + 0.1% of f.s
Mass Flow — Anode5 SLPM
Mass Flow — Cathode10 SLPM
Back Pressure ControlManual, 0–3 bar (accessory required)
Temperature RangeAmbient to 80°C (optional to 120°C)
Sensor TypeT-Type thermocouples (−185 to 300°C)
HumidifiersDual Sparger (Sintered SS316), 800W heaters
Temperature Accuracy±0.25% of span, ±1 LSD
Max. Whole Cell Voltage150 V
Operating Temperature5 to 40°C
Power Source240V AC, 50–60Hz, 6A
EnclosureSingle bench-top enclosure
Size & Weight~32″W × 30″D × 42″H, ~40 kg
Cell CompatibilityUp to 70 cm² PEM cells and short stacks
Gas Input Variants2 / 3 / 4 / 5 gas stream configurations

What's included

Electronic load — 80A, 400W, 0.25–150V
SS316 humidifiers with 800W heaters and automated DI water refilling
Mass flow controllers — Anode 5 SLPM, Cathode 10 SLPM with software control
Heated and insulated gas delivery lines
H₂ and CO leak sensors with automated controlled shutdown
Automated N₂ purge system for anode and cathode on shutdown
Manual backpressure control 0–3 bar (back pressure accessory required)
Temperature sensors — cell, humidifier and gas supply outlet (anode & cathode)
Control and data acquisition software
Emergency stop switch with automated shutdown logic
Individual shut-off valves for each gas line

Technical features

High-Power 400W Load

80A / 400W electronic load with 150V range — handles short stacks and large active area cells up to 70 cm²

Higher Flow Rate MFCs

Anode 5 SLPM and Cathode 10 SLPM mass flow controllers — 2.5× the flow capacity of the FCTS-165

800W High-Performance Humidifiers

Dual Sparger SS316 humidifiers with 800W heaters — delivers precisely humidified gases at higher flow rates

Optional High-Temperature Operation

Standard temperature range to 80°C with optional upgrade to 120°C for high-temperature PEM testing

Multi-Gas Stream Support

Available with 2, 3, 4 or 5 individual gas input streams for precise reactant purity control

Automated Safety Shutdown

Auto shutdown and N₂ purge on under-voltage, over-current, over-temperature, low water, pressure loss or comms failure

Dry or Humidified Gas

Supports both dry and humidified gas delivery to anode and cathode independently

Frequently asked questions

Ready to order the FCTS-400?
Our engineers will confirm specifications and lead time within 24 hours.
Send Enquiry →